Can-Am Instruments Ltd. : Sales and service for laboratory and environmental equipment
Home > Viscometers/Rheometers > Software

Brookfield Software

  Rheocalc


Automate your sample testing with Rheocalc Software and your DV-III Ultra or DV-II+ Pro.

Features:

  • Test Wizard for typical viscosity measurements
  • Primary screen allows quick single point viscosity determination
  • Automates data collection
  • Eliminates operator error when recording data
  • Creates a permanent record of each test
  • Unlimited data point collection
  • CGS or SI data units (cP or mPa·s)
  • Comparison data sets can be manually entered
  • Up to 5 data sets may be plotted simultaneously
  • Yield Stress Calculations (Bingham Plastic, Casson, Chocolate Casson), Power Law Consistency Index Calculations, Paste Analysis
  • Temperature control of sample with optional Brookfield TC Series Programmable Bath or Thermosel™ with Programmable Controller
  • Numerical display of measurement range for a selected spindle

    Computer Requirements:

  • Pentium PC, 500 mHz (faster PC recommended)
  • MS-Windows NT, 2000, XP
  • VGA/SVGA graphics
  • RS-232 port for rheometer; an optional second port needed for temperature control
  • Parallel port/USB for printer

Brochure (PDF)

 

Rheocalc
Click to enlarge



Rheocalc
Click to enlarge

 
  Wingather


Wingather software provides an easy way to gather data and plot graphs while creating permanent test records using your DV-I Prime and DV-II+/DV-II+ Pro series Viscometers.

Features:

  • DVLoader software for use with the DV-II+ PRO and Programmable DV-II+ now built right in
  • New ability to work with DV-I Prime
  • New ability to communicate to more than four COM ports with v3.0
  • New Plot component with a second Y axis provides more plotting and display options, including online plotting during data collection
  • New user-friendly interface with menus, toolbars and dockage control windows which can be resized and moved to create a custom display
  • Automates data collection
  • Eliminates operator error when recording data
  • Provides instantaneous viscosity flow curves (rheograms) on easy-to-read graphs
  • Creates a permanent record of each test
  • Data set size limited only by available disk space
  • Comparison data sets can be manually entered
  • Up to 5 data sets may be plotted simultaneously
  • Plot data available: % Torque, RPM, Viscosity, Shear Rate, Shear Stress, Temperature, Time
  • Yield Stress Calculations (Bingham Plastic, Casson, Chocolate Casson), Power Law Consistency Index Calculations, Paste Analysis
  • Graphical and numerical display of measurement range for a selected spindle
  • On-line help system

Computer Requirements

  • Pentium PC, 500 mHz (faster PC recommended)
  • MS-Windows NT, 2000, XP
  • VGA/SVGA graphics
  • RS-232 port for rheometer; an optional second port needed for temperature control
  • Parallel port/USB for printer

Brochure (PDF)

 

Wingather
Click to enlarge




Wingather
Click to enlarge


 
  DVLoader and RheoLoader


DVLoader: Supplied with all DV-II+ Pro Viscometers, DV Loader allows creation of programmed tests on a PC for download to the DV-II+ Pro.

RheoLoader: Supplied with all DV-III Ultra Rheometers, RheoLoader allows creation of customized test programs on a PC for download to the DV-III Ultra.

With both the DVLoader and RheoLoader:

  • Programs can be created, saved, printed, and downloaded from a PC to the viscometer
  • Great for Quality Control environments - programs can be created and downloaded by a QC supervisor to be later run by operators for consistency every time

Brochure (PDF)

 

DVLoader
DVLoader
Click to enlarge



RheoLoader
RheoLoader
Click to enlarge
 
  Capcalc


Capcalc turns your CAP2000+ Viscometer into an accurate rheometer for advanced sample analysis.

Features:

  • Test Wizard allows for easy, automated data collection to eliminate operator error
  • New BEAVIS commands — including Conditional Loop, Reporting Options, Data Averaging, and Set Spindle — now available with v3.0
  • Provides instantaneous viscosity flow curves (rheograms) on easy-to-read graphics
  • Records up to 1000 data points per test and creates a permanent test record in your choice of cP or mPas.
  • Plot up to four data sets simultaneously in 12 plot types
  • Yield Stress calculations (Bingham Plastic, Casson, Power Law, Consistency Index)
  • On-line help system in English, Spanish and Japanese
  • Save data in text, Lotus 1-2-3- and Excel
  • The ability to communicate to more than four COM ports
  • New Plot component with a second Y axis provides more plotting and display options, including online plotting during data collection
  • New user-friendly interface with menus, toolbars and dockage control windows which can be resized and moved to create a custom display

Computer Requirements

  • Pentium PC, 500 mHz (faster PC recommended)
  • MS-Windows NT, 2000, XP
  • VGA/SVGA graphics
  • RS-232 port for rheometer; an optional second port needed for temperature control
  • Parallel port/USB for printer

Brochure (PDF)

 

CapCalc
Click to enlarge



CapCalc
Click to enlarge
 
  EZ-Yield


This software is supplied with the YR-1 Rheometer and DV-III Ultra Rheometer to allow setup for up to 10 different yield stress test programs.

Features:

  • Simple parameter menu for set up of 10 different test programs.
  • Test parameters include: test number and name, spindle number, immersion mark level, pre-shear (rpm), wait time before test startup, run speed (rpm) and low and high yield stress control limits (Pa) for QC use.
  • Streaming data can be viewed and test data (torque vs. time, stress vs. strain) is displayed in both tabular and graphical formats on a PC.

Computer Requirements

  • Pentium PC, 500 mHz (faster PC recommended)
  • MS-Windows NT, 2000, XP
  • VGA/SVGA graphics
  • RS-232 port for rheometer
  • Parallel port/USB for printer

Brochure (PDF)

 

EZ-Yield
Click to enlarge



EZ-Yield
Click to enlarge
 
  Rheo 2000


Available for use with the R/S Plus Rheometers to automate sample testing and collect/analyze data.

Features:

  • Program by controlled stress or rate
  • Automate analysis of data collected
  • Calculate yield and average viscosity
  • Create flow curves and plot yield stress
  • Optional R/S Soft Solids Tester module for use with the R/S SST allows you to program for use with vane spindles and generate data such as yield point, shear modulus, creep and relaxation.

Computer Requirements

  • Pentium PC, 100 mHz, with 32 mb RAM
  • Windows 95, 98 or 200, NT
  • VGA Graphics card and monitor
  • Serial interface port RS232

Rheo 2000 Brochure (PDF)

NOTE: The Rheo 3000 has just been released!

 

Rheo R/S Software
Click to enlarge



Rheo R/S Software
Click to enlarge
 
  Rheovision


Powerful Rheovision Software is supplied with the PVS Rheometer for full automation and control of all test parameters and comprehensive data collection/analysis.

Simulate process conditions by measuring viscosity under pressure and temperature controlled environments using the PVS Rheometer and Rheovision software. Full automation and control of all test parameters are possible with this software, and it is included with the PVS Rheometer.

Features:

  • Automates data collection
  • Eliminates operator error when recording data
  • Provides instantaneous viscosity flow curves (rheograms) on easy-to-read graphs
  • Creates a permanent record of each test
  • Test data may be collected "in the background" while previous data may be viewed, printed, plotted, and analyzed.
  • Unlimited data point collection
  • CGS or SI data units
  • Comparison data sets can be manually entered
  • Data saved in Paradox™ database format or exported to MS-Excel™, HTML, Rich Text Format (RTF), or Comma Separated Values (CSV) formats
  • Up to 5 data sets may be plotted simultaneously
  • Plot data available: % Torque, RPM, Viscosity, Shear Rate, Shear Stress, Temperature, Time
  • Yield Stress Calculations (Bingham Plastic, Casson), Power Law Consistency Index Calculations, Paste Analysis
  • API calculations for oil and gas industry
  • Temperature control of sample (with optional temperature bath)
  • Graphical and numerical display of measurement range for a selected geometry

Computer Requirements

  • Pentium PC, 500 mHz (faster PC recommended)
  • MS-Windows NT, 2000, XP
  • VGA/SVGA graphics
  • RS-232 port for rheometer
  • Parallel port/USB for printer

Brochure (PDF)

 

RheoVision
Click to enlarge



RheoVision
Click to enlarge
 
  TexturePro CT


Take control of your CT3 Texture Analyzer with this powerful, easy-to-use software. Collect data and perform detailed data analysis with real time graphic plotting during the test. Easily create custom reports and graphs right from the menu screen.

Features:

  • Easily select test parameters
  • Database file structure for easy-to-manage files
  • Sample identification set-up screen helps new operators quickly get started; test method setup defines a variety of parameters
  • Intuitive set up for test methods and database file structures in a single window
  • Data is captured as a graph and stored in tabular database format
  • Advanced data analysis with built-in parameter calculations such as springiness, chewiness, hardness and much more!
  • Evaluate mean and standard deviation of each result parameter for up to 30 samples

Computer Requirements

  • 800 MHz or better Pentium processor
  • 30MB of available Hard drive space
  • 512 mB RAM
  • Windows 2000, XP, or Vista operating system
  • One USB or RS-232 port

Brochure (PDF)

 



TexturePro
Click to enlarge